ITEM
|
Parameter
|
Mixing ratio
|
1:1--10:1 adjustable
|
Working range
|
700*700*100mm
|
Displacement speed
|
250mm/s(speed)
|
Out-glue speed
|
1-12g/s per single pump
|
Accuracy
|
±2%(output volume)±2%(mixing)
|
tolerance
|
≤0.2mm
|
Flow control
|
Digital input
|
Program memory
|
99pcs-999pcs
|
Motion trail
|
Dot , line ,curve ,circle
|
Automatic controlling system
|
Touch screen (to achieve program programming, modification, storage and so on
|
Out-glue control system
|
AB glue back suction valve, achieve AB glue independent operation
|
Programmatically
|
Tech programming/or computer systems (Micro software Windows 7,Windows10 optional)
|
Mixing method
|
dynamic mixing
|
Power supply
|
220V/50Hz/1500W without heating
|
Air source
|
0.5-0.8Mpa
|
Viscosity range
|
50-20000cps
|
Outer dimension
|
1500L*1200W*1600H mm
|
A tank
|
10L 25L 40L stainless tank(optional)
|
B tank
|
10L 25L 40L stainless tank(optional)
|
Others
|
AB tank ,A pump,AB pipeline heating function
|
Drops always happened when valve closed . The reason may be low concentration of glue , big air-pressure or large diameter of needles.
Narrow needles will effect the flow of the liquid and cause back pressure . It will lead to dropping when the valve closed . Too narrow needles will effect the drainage of air when valve start to work, but it can be solved if change suitable needles .
Conical needles with less back pressure and liquid flow smoothly .
It is better to drainage of the air advance or use no-foam glue or deaeration to avoid the air cause dropping after valve closed .
The problem cause mainly because of the storage flow pressure tank or air pressure is not stable.
Inlet pressure regulating table should be set lower 10-15psi than factory minimum pressure . The pressure in pressure tank should be set upper than the middle pressure of regulating table . It should be avoided to use the pressure lower than the middle pressure of regulating table .
Control pressure of rubber valve at least higher than 60psi to assured glue evenly .
We should check the glue output speed at last . The glue is uneven if the time less than 15/1000s , the output speed more longer , the glue dispensing will be more stable .
It should be changed the pipe from 1/4 to 3/8 if the flow velocity too slowly .
The pipe is the shorter the better if no requirement .
Excessive fluid pressure and short valve opening time may lead to the air infiltration liquid . We can use the conical needles and reduce fluid pressure .
This problem is caused by heavy moisture and recycle instant glue . We should make sure to use new instant glue and wash the pipes with dry acetone . Make sure air dry and add filter between plant air pressure and valve .
Make sure to use black pipeline.
Don't add new UV glue to old UV glue in pressure tank , we should drain off the old UV glue before pouring new UV glue into pressure tank because the UV glue will produce bubble after a period of time and lead to glue dispensing unevenly .
Normally , it may cause air problem if the needle less than NO.20 . It is better to use large steel needles or conical needles to avoid to use winding needles needles
It is better to use storage pressure cylinder of methybenzene toluene to self-cleaning one time for each shift . The more frequently cleaning the better .